bg Hanna Low Range pH/Conductivity/TDS Tester - Brewing Gadgets

REFERENCE: Hanna Low Range pH/Conductivity/TDS Tester

Hanna Low Range pH/Conductivity/TDS Tester

AED 819 VAT Incl.

or 4 interest-free payments of AED 19.50. No fees.
Shariah-compliant. Learn More.

COD Eligable, If Cart Value In Between AED 200 to 1000

Deliver to: By: 27 Jul 24 to

SKU: Hanna Low Range pH/Conductivity/TDS Tester Categories: ,

• pH Range : 0.00 to 14.00 pH
• pH Resolution : 0.01 pH
• pH Accuracy (@25ºC/77ºF) : ±0.05 pH
• Conductivity Range : 0 to 3999 µS/cm
• Conductivity Resolution : 1 µS/cm
• Conductivity Accuracy (@25ºC/77ºF) : ±2% F.S.
• TDS Range : 0 to 2000 ppm (mg/L)
• TDS Resolution : 1 ppm (mg/L)
• TDS Accuracy : ±2% F.S.
• Temperature Range : 0.0 to 60.0°C / 32.0 to 140.0°F
• Temperature Resolution : 0.1°C / 0.1°F
• Temperature Accuracy (@25ºC/77ºF) : ±0.5°C /±1°F
• EC/TDS Calibration: automatic, one-point at : 1413 µS/cm, 1382 ppm (mg/L)
• pH Calibration : automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
• Temperature Compensation : pH: automatic; EC/TDS: automatic with β adjustable from 0.0 to 2.4% / °C
• TDS Conversion Factor : 0.45 to 1.00
• pH Electrode : HI73127 (replaceable; included)
• Battery Type/Life : 1.5V (4) / approx. 100 hours of continuous use, auto-off after 8 minutes of non-use
• Environment : 0 to 50°C (32 to 122°F); RH max 100%
• Dimensions : 163 x 40 x 26 mm (6.4 x 1.6 x 1.0’’)
• Weight : 100 g (3.5 oz.)
• Ordering Information : HI98129 is supplied with HI73127 pH electrode and HI73128 electrode removal tool, batteries (4 x 1.5V) and instructions.
• Warranty : 1 year

The HI98129 is an easy-to-use and accurate waterproof pH, conductivity, TDS (ppm) tester. It measures pH, EC in the low range (0 to 3999 µS/cm), TDS (0 to 2000 ppm), and temperature. This floating, waterproof combination pocket tester has an easy to read, LCD and an automatic shut-off. All pH, EC, and TDS (ppm) readings are automatically temperature compensated (ATC) to prevent temperature-related variations in your measurements. For EC and TDS (ppm) readings, the EC/TDS conversion factor (CONV) is selectable by the user, as well as the temperature compensation coefficient β (BETA).

Replaceable pH Electrode Cartridge
The HI98129 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!

High Accuracy EC and TDS (ppm) Tester Probe
The graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits in the solution. The exposed temperature sensor provides fast response times and guarantees highly accurate temperature compensated readings.

Features at-a-glance
• 3 sensors in a single tester
• pH electrode with extractable junction
• Amperometric EC/TDS sensor
• Exposed temperature probe for faster EC and TDS (ppm) readings

Waterproof
• Designed to float if accidently dropped in sample

Wide pH Range
• pH range is from 0.00 to 14.00 pH

Selectable EC to TDS (ppm) conversion factor
• Choice of either a 0.45 or 1.0 conversion factor

Automatic Temperature Compensation
• All readings are compensated for variations in temperature
• Temperature displayed in oC or oF along with pH, EC or TDS reading

Stability indicator
• Meter displays a clock tag that will disappear when the reading has achieved stability

HOLD button
• Freezes reading on the display to allow recording of measurement

BEPS (Battery Error Prevention System)
• Meter will automatically shut off if there is not enough power to get an accurate measurement

Battery % level at startup
• Low Battery Indicator
• When the level is below 5%, the  battery symbol on the LCD blinks to indicate a low battery condition.

 Auto-off
• Auto-off  feature automatically shuts off  meter after 8 minutes of non-use to maximize battery life

Secure Payment

Lorem ipsum dolor sit amet, consetetur

Secure Payment

Lorem ipsum dolor sit amet, consetetur

The HI98129 is an easy-to-use and accurate waterproof pH, conductivity, TDS (ppm) tester. It measures pH, EC in the low range (0 to 3999 µS/cm), TDS (0 to 2000 ppm), and temperature. This floating, waterproof combination pocket tester has an easy to read, LCD and an automatic shut-off. All pH, EC, and TDS (ppm) readings are automatically temperature compensated (ATC) to prevent temperature-related variations in your measurements. For EC and TDS (ppm) readings, the EC/TDS conversion factor (CONV) is selectable by the user, as well as the temperature compensation coefficient β (BETA).

Replaceable pH Electrode Cartridge
The HI98129 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!

High Accuracy EC and TDS (ppm) Tester Probe
The graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits in the solution. The exposed temperature sensor provides fast response times and guarantees highly accurate temperature compensated readings.

  • Features at-a-glance
    3 sensors in a single tester
    pH electrode with extractable junction
    Amperometric EC/TDS sensor
    Exposed temperature probe for faster EC and TDS (ppm) readings
  • Waterproof
    Designed to float if accidently dropped in sample
  • Wide pH Range
    pH range is from 0.00 to 14.00 pH
  • Selectable EC to TDS (ppm) conversion factor
    Choice of either a 0.45 or 1.0 conversion factor
  • Automatic Temperature Compensation
    All readings are compensated for variations in temperature
    Temperature displayed in oC or oF along with pH, EC or TDS reading
  • Stability indicator
    Meter displays a clock tag that will disappear when the reading has achieved stability
  • HOLD button
    Freezes reading on the display to allow recording of measurement
  • BEPS (Battery Error Prevention System)
    Meter will automatically shut off if there is not enough power to get an accurate measurement
  • Battery % level at startup
  • Low Battery Indicator
    When the level is below 5%, the  battery symbol on the LCD blinks to indicate a low battery condition.
  • Auto-off 
    Auto-off  feature automatically shuts off  meter after 8 minutes of non-use to maximize battery life
Pattern / Type

Standard

Brand

Hanna Instruments

Frequently Asked Questions

SHOPPING CART
BOOK A SERVICE

Book A Service

Required Field !

Required Field !

Required Field !

Required Field !

Required Field !

Required Field !

Required Field !

Required Field !

Loading...

Download Quotation

Required Field !

Required Field !

Required Field !

Loading...
Scroll to Top