• pH Range : 0.00 to 14.00 pH
• pH Resolution : 0.01 pH
• pH Accuracy (@25ºC/77ºF) : ±0.05 pH
• Conductivity Range : 0 to 3999 µS/cm
• Conductivity Resolution: 1 µS/cm
• Conductivity Accuracy (@25ºC/77ºF): ±2% F.S.
• TDS Range: 0 to 2000 ppm (mg/L)
• TDS Resolution: 1 ppm (mg/L)
• TDS Accuracy: ±2% F.S.
• Temperature Range: 0.0 to 60.0°C / 32.0 to 140.0°F
• Temperature Resolution: 0.1°C / 0.1°F
• Temperature Accuracy (@25ºC/77ºF): ±0.5°C /±1°F
• EC/TDS Calibration: automatic, one-point at: 1413 µS/cm, 1382 ppm (mg/L)
• pH Calibration: automatic, at one or two points with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18)
• Temperature Compensation: pH: automatic; EC/TDS: automatic with β adjustable from 0.0 to 2.4% / °C
• TDS Conversion Factor: 0.45 to 1.00
• pH Electrode: HI73127 (replaceable; included)
• Battery Type/Life: 1.5V (4) / approx. 100 hours of continuous use, auto-off after 8 minutes of non-use
• Environment: 0 to 50°C (32 to 122°F); RH max 100%
• Dimensions: 163 x 40 x 26 mm (6.4 x 1.6 x 1.0’’)
• Weight: 100 g (3.5 oz.)
• Ordering Information: HI98129 is supplied with HI73127 pH electrode and HI73128 electrode removal tool, batteries (4 x 1.5V) and instructions.
• Warranty: 1 year
The HI98129 is an easy-to-use and accurate waterproof pH, conductivity, TDS (ppm) tester. It measures pH, EC in the low range (0 to 3999 µS/cm), TDS (0 to 2000 ppm), and temperature. This floating, waterproof combination pocket tester has an easy to read, LCD and an automatic shut-off. All pH, EC, and TDS (ppm) readings are automatically temperature compensated (ATC) to prevent temperature-related variations in your measurements. For EC and TDS (ppm) readings, the EC/TDS conversion factor (CONV) is selectable by the user, as well as the temperature compensation coefficient β (BETA).
Replaceable pH Electrode Cartridge
The HI98129 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!
High Accuracy EC and TDS (ppm) Tester Probe
The graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits in the solution. The exposed temperature sensor provides fast response times and guarantees highly accurate temperature compensated readings.
Features at-a-glance
• 3 sensors in a single tester
• pH electrode with extractable junction
• Amperometric EC/TDS sensor
• Exposed temperature probe for faster EC and TDS (ppm) readings
Waterproof
• Designed to float if accidently dropped in sample
Wide pH Range
• pH range is from 0.00 to 14.00 pH
Selectable EC to TDS (ppm) conversion factor
• Choice of either a 0.45 or 1.0 conversion factor
Automatic Temperature Compensation
• All readings are compensated for variations in temperature
• Temperature displayed in oC or oF along with pH, EC or TDS reading
Stability indicator
• Meter displays a clock tag that will disappear when the reading has achieved stability
HOLD button
• Freezes reading on the display to allow recording of measurement
BEPS (Battery Error Prevention System)
• Meter will automatically shut off if there is not enough power to get an accurate measurement
Battery % level at startup
• Low Battery Indicator
• When the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.
Auto-off
• Auto-off feature automatically shuts off meter after 8 minutes of non-use to maximize battery life
In 1978 Hanna Instruments was founded in Limena, Italy by Oscar and Anna Nardo. Since that time, Hanna Instruments has grown to be a worldwide leader in the development of electro-analytical instrumentation. Hanna has produced simple, affordable, high quality devices for laboratory, food, agriculture, aquarium, environmental, industry applications. Hanna offer a wide array of instrumentation from research grade benchtop meters and ISEs, to single and multiparameter meters for pH, DO, and more.
• pH Tester with 0.1 pH Resolution – HI98107:
• pH Range : 0.0 to 14.0 pH
• pH Resolution : 0.1 pH
• pH Accuracy : ±0.1 pH
• pH Calibration : Automatic, one or two points
• pH Temperature Compensation : Automatic, 0 to 50 oC (32 to 122°F)
• Temperature Range : 0 to 50 oC (32.0 to 122.0oF)
• Temperature Resolution : 0.1 oC / 0.1 °F
• Temperature Accuracy : ±0.5 oC / ±1.0 °F
• Automatic Shut-Off : 8 minutes, 60 minutes, or disabled
• Battery Type/Life : CR2032 3V Li-Ion (1 pc.) / approximately 800 hours of use
• Environment : 0 to 50°C (32 to 122°F); RH max 100%
• Dimensions : 160 x 40 x 17 mm (6.3 x 1.6 x 0.7″)
• Weight : 65 g (2.3 oz.) without battery
• Ordering Information : The HI98107 is supplied with protective cap, pH 4.01 buffer sachet, pH 7.01 buffer sachet (2), electrode cleaning sachet, CR2032 battery, instrument quality certificate and instructional manual.
• TDS Tester (0-2000 ppm) – HI98301
• TDS Range : 0 to 2000 ppm (mg/L)
• TDS Resolution : 1 ppm (mg/L)
• TDS Accuracy : ±2% F.S.
• TDS Calibration : automatic, one point at 1382 ppm
• EC/TDS Temperature Compensation : automatic from 0 to 50°C (32 to 122°F)
• Temperature Correction Coefficient : 1.9%/°C
• EC to TDS Conversion Factor : 0.5
• Temperature Range : 0.0 to 50.0°C (32.0 to 122.0°F)
• Temperature Resolution : 0.1°C (0.1°F)
• Temperature Accuracy : ±0.5°C (±1°F)
• Automatic Shut-Off : 8 minutes, 60 minutes, or disabled
• Battery Type/Life : CR2032 3V Li-Ion (1 pc.) / approximately 250 hours of continuous use
• Environment : 0 to 50°C (32 to 122°F); RH 100%
• Dimensions : 160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)
• Weight : 68 g (2.4 oz.) without battery
• Ordering Information : HI98301 is supplied with protective cap, 1382 ppm calibration solution sachet (4), CR2032 battery, instrument quality certificate and instructional manual.
pH Tester with 0.1 pH Resolution – HI98107:
The Hanna Instruments HI98107 pHep® pH tester is a rugged and reliable pocket-sized tester for use in the lab or field. This modern looking meter is only 0.7″ thick and extremely ergonomic, fitting comfortably in your hand. This tester keeps things simple with a two-button operation; one for ON/OFF, the other for Calibration.
TDS Tester (0-2000 ppm) – HI98301:
The Hanna Instruments HI98301 DiST 1 is a low-range total dissolved solids tester than can measure up to 2000 ppm (mg/L). The DiST 1 is a rugged and reliable pocket-sized tester for use in the lab or field. This modern looking meter is only 0.7″ thick and extremely ergonomic, fitting comfortably in your hand. The HI98301 DiST 1 has a 0.5 conversion factor in the measurement of TDS in a variety of applications including water conditioning, environmental monitoring, education and general laboratory use. This tester keeps things simple with a two-button operation; one for ON/OFF, the other for calibration.
In 1978 Hanna Instruments was founded in Limena, Italy by Oscar and Anna Nardo. Since that time, Hanna Instruments has grown to be a worldwide leader in the development of electro-analytical instrumentation. Hanna has produced simple, affordable, high quality devices for laboratory, food, agriculture, aquarium, environmental, industry applications. Hanna offer a wide array of instrumentation from research grade benchtop meters and ISEs, to single and multiparameter meters for pH, DO, and more.
• Product Name : HI770710P pH 4.01 & 7.01 Calibration Buffer & Conductivity Solution
• Quote Required : No
• Description : Standard calibration buffer
• Certificate of Analysis : No
• pH Accuracy : ±0.01 pH
• pH Value @ 25°C:7.01; 10.01
• Package sachets Quantity : 3 (1 each)
• Size : 20 mL
Calibration Buffer Solutions-Hanna Instruments
Maximum accuracy is high on the agenda here at Hanna. Browse our Conductivity Calibration Solutions specifically produced for Conductivity meters and electrodes.
Hanna conductivity electrodes can be calibrated in just a few minutes, wherever you are working, thanks to our range of conductivity solutions in different forms and values. Sachets, for instance, could be very useful out in the field as well as the laboratory.
Each label shows the product batch number, expiry date, and a conductivity/temperature correlation table. EC value is calculated at 25C.
HI770710P is a set of premium quality pH 7.01 and 10.01 calibration buffers produced in accordance with ISO 3696/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are accurate to +/- 0.01 pH @ 25°C and are traceable to NIST Standard Reference Materials (SRMs).
Convenience of individual packaging
• Ideal for users that do not calibrate frequently
• Ideal for field use due to portability
• Every sachet is as fresh as the day it was packaged
• Light block packaging prevents oxidation from UV light that could alter the buffer value
Each sachet marked with lot number and expiration date.
• Hanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.
Light block packaging
• Prevents any oxidation from UV light that could alter the buffer value.
Color coded label for easy pH buffer value identification.
• Easy to identify different buffer values
• Solution does not contain any dyes that may stain the reference cell of a pH electrode
In 1978 Hanna Instruments was founded in Limena, Italy by Oscar and Anna Nardo. Since that time, Hanna Instruments has grown to be a worldwide leader in the development of electro-analytical instrumentation. Hanna has produced simple, affordable, high quality devices for laboratory, food, agriculture, aquarium, environmental, industry applications. Hanna offer a wide array of instrumentation from research grade benchtop meters and ISEs, to single and multiparameter meters for pH, DO, and more.